Description:

DTC CodeDTC Detection ConditionTrouble Area
P0711Either condition is met (2-trip detection logic):
(a) Certain monitor enabling conditions are met and the ATF temperature is below 20°C (68°F).(b) Certain monitor enabling conditions are met and the ATF temperature is 110°C (230°F) or higher.
Transmission wire (No. 1 ATF temperature sensor)

Typical enabling conditions:

The monitor will run whenever the following DTCs are not present: P0712, P0713, P2740, P2742, P2743 (ATF temperature sensor “A” circuit)
P0115, P0116, P0117, P0118, P011B (ECT (Engine Coolant Temperature) sensor circuit)
P0110, P0111, P0112, P0113 (IAT (Intake air temperature) sensor circuit)
P2610 (Soak timer circuit)

Codition (A):

Duration time from engine start12 seconds or more
ECT-15°C (5°F) or higher
Permission flag for ATF temperature rationality checkON
Time after engine start except for continuing shift position “N” or “P”*25 minutes or more
Accumulated driving time*175 seconds or more
Driving distance after engine start*34.7 km (3.0 miles) or more
ECT (12 seconds after engine start)15°C (59°F) or higher
IAT*415°C (59°F) or higher
Soak time5 hours or more

Condition (B):

Duration time from engine start12 seconds or more
ECT-15°C (5°F) or higher
Permission flag for ATF temperature rationality checkON
Time after engine start except for continuing shift position “N” or “P”*221 minutes and 40 seconds or more
Accumulated driving time*1140 seconds or more
Driving distance after engine start*39.0 km (5.6 miles) or more
ECT (12 seconds after engine start)-10°C (14°F) or higher
IAT*4-10°C (14°F) or higher

Condition (C):

Duration time from engine start12 seconds or more
ECT-15°C (5°F) or higher
Permission flag for ATF temperature rationality checkON
Time after engine start except for continuing shift position “N” or “P”*230 minutes or more
Accumulated driving time*1400 seconds or more
Driving distance after engine start*316.0 km (9.9 miles) or more
ECT (12 seconds after engine start)-15°C (5°F) or higher
IAT*4-15°C (5°F) or higher

Condition (D):

Duration time from engine start12 seconds or more
ECT-15°C (5°F) or higher
Permission flag for ATF temperature rationality checkON
Time after engine start except for continuing shift position “N” or “P”*255 minutes or more
Accumulated driving time*1750 seconds or more
Driving distance after engine start*327.0 km (16.8 miles) or more

Condition (E):

Duration time for ECT to reach 60°C (140°F)10 seconds or more
ATF temperature (12 seconds after engine start)110°C (230°F) or higher
ECT (12 seconds after engine start)Below 35°C (95°F)

Datalist:

Tester DisplayMeasurement Item/RangeNormal ConditionDiagnostic Note
A/T Oil Temperature 1No. 1 ATF temperature sensor value/
Min.: -40°C (-40°F)
Max.: 150°C (302°F)
·After stall test: Approximately 80°C (176°F)·Equal to ambient temperature when engine coldIf the value is -40°C (-40°F) or 150°C (302°F), the No. 1 ATF temperature sensor circuit is open or shorted.

Procedure:

1. Check DTC output

ResultProceed to
Only P0711 is outputA
P0711 and other DTCs are outputB

A>> Check transmission fluid level.
B>> Go to DTC chart.

2. Check transmission fluid level.
a. Check the transmission fluid level.
a.1. Automatic transmission fluid level is correct.
OK>> Repair or replace transmission wire.
NG>> Add fluid.